We use cookies to Improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Home > VG Series Cover Sizing & Sealing Guide

VG Series Cover Sizing & Sealing Guide

Oil Tank Access Cover

VG Series Cover Sizing & Sealing Guide

Selection starts with the opening you already have: measure the tank port, match it to the published A dimension, then confirm the seal stack before you buy. Every oil tank access cover in the VG range is an aluminium cover supplied with a welding flange and built-in sealing rings for direct side sealing, and each oil tank cleaning cover is removable for internal cleaning, corrosion-resistant to HFC medium and tightened to a maximum of 10 Nm.

5 sizesVG250F through VG560F
10 Nm maxScrew tightening torque
AluminiumHFC-resistant body
Oil tank cleaning cover (VG)

Have your opening diameter? Start with the model that matches it.

The figures published for each model describe the cover and its flange, not the hole you cut in the tank. Measure the opening itself — inside diameter, on a clean, unloaded reservoir — before you match a model.

Series attributes

What the VG Series Gives You Before Size Is Decided

Size only solves half the problem. This table settles the mechanical questions first — seal style, mounting side, media resistance and service access — so the dimension matrix below is the last step rather than the first.

VG tank cleaning cover showing the flange face and sealing arrangement
Flange face and sealing arrangement on the VG cleaning cover — the side that has to mate cleanly with your tank port.
Component typeCleaning cover / inspection cover
FunctionInspection access and internal maintenance
Seal typeHigh-reliability industrial gasket, with built-in sealing rings
MaterialAluminium, listed as anti-corrosion industrial grade
Mounting positionEither or both sides of the oil tank
Flange connectionSupplied with welding flange; order description lists sealing O-rings
Media resistanceCorrosion-resistant to HFC medium
Removable for cleaningYes — the cover lifts away so impurities inside the tank can be removed
Screw torqueMaximum 10 Nm on all cleaning cover installation screws
Maintenance profileEasy access / fast removal, intended to cut downtime on routine inspection

Which column applies to me? All of it — these attributes hold across the whole VG family, so a seal or mounting mismatch is a reason to stop and ask, not a reason to change size.

Dimension matrix

VG250F to VG560F: Every Published Dimension in One Table

One row per model, one column per dimension, plus the welding flange thickness that stays constant across the range.

Unit note: the values below are reproduced exactly as Meison Hydraulic publishes them for the VG series, and the product page does not restate a unit column beside the figures. Treat them as metric, and confirm the unit against your tank drawing and the order description before you commit to a purchase.

Model A B C D E F Welding flange thickness
VG250F25022517516070617
VG300F300275225210120617
VG350F350325275260130617
VG475F475449395278158817
VG560F5605304803002001217

Read the model number against column A: VG250F carries an A value of 250, VG300F of 300, and so on up to VG560F at 560. That one-to-one pattern is the fastest sanity check that you are looking at the right row.

Reading the drawing

Three Measuring Rules Before You Open the Matrix

Most wrong orders are not wrong calculations — they are measurements taken against the wrong feature. These three rules catch the common cases.

VG oil tank cleaning cover viewed to show the port opening and flange thickness
Measure the tank port, not the cover: the opening you have to close is what selects the model.
RULE 01

Measure the opening, not the old cover

A caliper across the tank port gives you the dimension that selects a model. Copying the outside diameter of a cover you already own can put you one size out, because the published figures describe the cover and its flange, not the aperture beneath it.

RULE 02

Separate flange thickness from tank wall

The welding flange thickness is a fixed 17 across every VG model, and it is a property of the cover, not of your plate. Record your tank wall thickness separately — the two numbers end up in the same conversation but they are not interchangeable.

RULE 03

Measure clean, empty and unloaded

Take the reading on a drained, depressurised reservoir at ambient temperature. A tank under load or holding warm fluid can read differently at the port, and that error transfers straight into the model you pick.

Sealing & torque

Six Rules That Keep the Cover Leak-Free

Fit is a purchase decision; sealing is an installation decision. These six rules cover what the VG design does for you and what it still expects from the person holding the wrench.

Close view of the VG oil tank cleaning cover sealing face and screw positions
Gasket at the flange, sealing rings at the body — both compress under the installation screws.
RULE 01

Stop at 10 Nm

Maximum tightening torque for all cleaning cover installation screws is 10 Nm. Going past it distorts the sealing face and the gasket does the opposite of what you intended.

RULE 02

Seal at two places

The flange and the junction are both sealed with rubber gaskets, stated as heat-resistant and leak-proof. Check both faces, not just the one you can see from above.

RULE 03

Use the built-in ring for side sealing

Built-in sealing rings allow direct side sealing of the oil tank, so a side-mounted cover does not depend on a separate seal you have to source and align.

RULE 04

Seat the O-ring square

The order description lists sealing O-rings with the welding flange. A ring that is pinched rather than seated is the usual cause of a slow weep after an otherwise correct installation.

RULE 05

Close the door on dust and moisture

The gasket materials are specified to hold an airtight, leak-proof seal that keeps contamination from dust and moisture out of the reservoir — which matters most on outdoor and mobile equipment.

RULE 06

Plan the gasket as a service item

The cover is built for fast removal, so budget for a fresh gasket each time the tank is opened for cleaning rather than re-compressing one that has already taken a set.

Scenario to specification

Match Your Tank to the Cover Configuration

Four situations cover most VG enquiries. Each one points to a specific attribute on the cover and the decision you then have to make.

Stationary hydraulic power unit, cleaned on schedule

Specification that matters
Removable cover with a high-reliability industrial gasket and built-in sealing rings.
Buyer decision
Choose the model from column A that matches the port, and plan the gasket as a consumable — access speed is the whole point of this configuration.

Gearbox or bearing lubrication tank

Specification that matters
Airtight, leak-proof seal that prevents contamination from dust and moisture.
Buyer decision
Prioritise the seal stack over size convenience: a cover one size up is useless if the joint weeps into the lubricant.

Chemical, processing or power plant tank

Specification that matters
Aluminium body with corrosion resistance to HFC medium, plus heat-resistant gaskets.
Buyer decision
Confirm your medium and operating temperature with the sales team before ordering — media compatibility is a stop/go question, not a preference.

Mobile hydraulic retrofit in the field

Specification that matters
Either-side mounting with a welding flange and sealing O-rings, torqued to 10 Nm.
Buyer decision
Decide left side, right side or both before fabrication, and carry a torque wrench to 10 Nm — field fitting is where over-torquing happens.

Before you order

Four Failure Points That Cost the Most

Each of these is cheap to avoid on paper and expensive to fix on a commissioned tank.

  • Ordering from the old cover's dimensions. Measure the port in the tank, then read column A. A cover lifted from a similar unit is not a measurement.
  • Mixing up flange thickness and wall thickness. The welding flange thickness is fixed at 17 across the range; your plate thickness is your number to record separately.
  • Tightening past 10 Nm. The screws have a stated maximum. Beyond it, the gasket is crushed unevenly and the leak appears after the tank is filled, not before.
  • Reusing a compressed gasket. The cover is designed for fast, repeatable removal — treat the gasket as a service part and the seal stays predictable.

Send Your Opening Diameter and Medium — We Confirm the Model

Give the team three things: the inside diameter of your tank opening, the fluid and operating temperature, and which side the cover mounts on. You get back a confirmed model, seal configuration and a quotation. The same contact route handles bulk orders and OEM enquiries for reservoirs built to your own drawing.

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

How to Choose a VG Series Hydraulic Tank Cleaning Cover

A standard VG hydraulic tank cleaning cover should be selected from the reservoir opening outward, using the sidewall space, bolt pattern, fluid, and maintenance routine to eliminate models before…

Read article

Screening Oil Tank Access Cover Manufacturers for OEM Reservoirs

OEM sourcing managers and hydraulic engineers screening oil tank access cover manufacturers need a clear view of welding flange fit, CNC machining consistency, standard VG model coverage, gasket…

Read article

Custom Oil Tank Cleaning Covers for Nonstandard Tank Openings

A retrofit tank opening rarely matches a catalog drawing, so a custom cover inquiry should begin with measured dimensions rather than price alone.

Read article

Frequently Asked Questions

What information is shown for this product?

Review the product details, images, and specifications presented on the official product page.

Where can i check the intended application?

Use the application and use-case information published on the official product page.

Which specifications should i confirm before ordering?

Confirm the specifications and options listed for the exact product variant before placing an order.

Where can i check available options?

Check the official product page or ask the supplier about options shown for the selected product.

How can i request product information?

Use the official contact or inquiry path provided on the site.

What should i include in an inquiry?

Include the product page, intended use, required quantity, and any specifications you need the supplier to review.