Product Overview
Every DC Series cooler is a shell and tube oil cooler. Oil enters the cylindrical body and is turned through a helical path by a set of spiral guide plates; cooling water passes through a bundle of finned tubes running the length of that body. The fins multiply the wetted surface on each tube, and the guide plates stop the oil from channelling straight from inlet to outlet, so the whole bundle does an even share of the work and the oil leaves at a steady temperature instead of arriving in hot slugs. We are oil cooler manufacturers, so the shell, the bundle and the sealing are built as one matched assembly — the clearances and the seal faces are set together at the works rather than assembled from parts bought to three different tolerances.
Where a machine already has a water supply — a plant cooling loop, a chiller, or a process water line — water cooled oil coolers are usually the compact and quiet answer. There is no fan, no fan noise, and no air path to keep clear when the unit sits inside a closed power pack or below deck. Holding the oil inside its working band is also what slows oxidation, so pumps, valves and seals last longer on the same oil. Where there is no water and none can be run to the machine, an air-cooled cooler is the right choice and this series is the wrong one to order. The two are decided on the site services, not on the price list.
What arrives is a painted cylindrical body with bolted, flanged end caps at each end and U-shaped brackets for mounting. The ports are capped for transit. The finned tubes are visible as soon as an end cap comes off, which is also how the water side is opened for cleaning.
- Finned tube surface: each tube in the bundle carries fins, which multiplies the area in contact with the oil for a given shell length; that surface, not the shell diameter, is where most of the exchange rate comes from. - Spiral guide plates: oil is turned into a helical path instead of running straight through, so it sweeps the full length of the bundle, stays against the tube surface longer, and leaves no stagnant pocket to overheat. - Steady outlet temperature: even flow across an even surface keeps oil temperature flat through a shift instead of cycling between hot and cool as the load changes. - Compact for the duty: a water-cooled shell holds a heavy heat load in a small envelope, which matters when the cooler has to live inside a machine base or on a crowded power unit. - Sealed, bolted construction: flanged end caps and sealed joints keep the oil side and the water side apart under load, and the caps can be opened for tube access without disturbing the mounting. - Pressure resilience: the housing and sealing are built for both low-pressure return lines and higher-pressure circuits; tell us the working pressure of your circuit when you specify. - Hydraulic or lubrication duty: the same core serves hydraulic oil and lube oil cooler duty, so one series covers the hydraulic power unit and the lubrication circuit on the same machine. - Horizontal or vertical mounting: the unit installs either way, so a crowded frame does not have to be redesigned around the cooler.
The MEISON Advantage
- Made, not resold: we are oil cooler manufacturers, so every shell and tube oil cooler is built as one assembly at our own works in Foshan, Guangdong — shell, bundle and sealing — rather than bought in and badged.
- A track record on this series: more than 820 units shipped, rated 5.0 across 42 buyer reviews.
- Scale behind the model: over one million units supplied to more than 6,000 customers worldwide.
- Engineering depth: more than 60 technical patents across the hydraulic component range, which is why an awkward duty gets an engineered answer rather than the nearest catalogue size.
- One order, one build: accumulator, coupling, bell housing and tank access cover come from the same source, so a power unit does not have to be split across three suppliers.
- Testing and packing under one roof: what was pressure-tested is what goes into the crate, because both happen at the same works.
Tube Grade & Water Quality
The tube bundle, not the oil, decides how long a shell and tube oil cooler lasts. Standard units are built with copper tubes for fresh water — a cooling tower, a closed loop or a treated plant supply. Copper-nickel tubes are the grade for brackish, saline or chemically aggressive water, where plain copper would pit and thin. Both are corrosion-resistant; the choice is made against the water, and the wrong grade fails long before the shell does.
If you are on sea water, river water or a specific process stream, send the source, the chloride level, the normal water temperature and whether the flow is continuous or intermittent. Where none of the standard grades is right, the bundle and the water-side materials are built to that stream as a custom oil cooler — the answer is a different alloy, not a larger shell.
Water-side fouling is a materials question as much as a maintenance one. Scale and silt insulate the tubes, and the resulting rise in oil temperature is often read as a cooler that is too small, when it is a cooler that is dirty or a bundle that was specified against the wrong water. Settling the grade at the order stage costs far less than replacing a bundle two seasons in.
Installation & Commissioning
- Decide where the unit sits before any pipe is run, and keep the end caps reachable — that is the end that opens for tube cleaning, and it is the mistake that costs most to correct later.
- Mount the body on its U-shaped brackets to the frame or floor and support the shell along its length; do not let the unit hang on its pipework.
- Flush the water line before connecting it. Grit, mill scale and joint compound from new pipework are the most common reason a tube blocks in the first season.
- Connect oil and water to the ports marked on the shell, using the connection sizes in the model table, and fit isolation valves on the water side so the unit can be taken out of service without draining the whole loop.
- Fill and vent the water side, bring the circuit up to temperature slowly, then check every oil cooler hydraulic connection — flanges and threaded joints — for weeps.
- Run the machine under normal load and record four readings: oil in, oil out, water in, water out. Those four numbers are the baseline for every comparison you make later.
- Ask us whether your circuit needs a bypass or relief path across the cooler; where the unit can be isolated, a bypass keeps oil moving while the water side is being cleaned.
Application Scenarios
- Power turbines and compressor skids: control and lubricating oil has to hold a narrow band through load swings, and the station cooling water is already at hand, so the shell ties straight into it.
- Marine and offshore machinery: below-deck spaces have no clean air path and no room for a fan, so the water side does the work on winch, deck machinery and gearbox circuits that run for long stretches without a break.
- Steel mills, foundries and press shops: the air in the bay is hot and dirty, which is exactly when a fan-cooled unit loses efficiency; a water-cooled shell is unaffected by the air around it.
- Injection moulding and extrusion lines: holding oil viscosity steady holds part quality steady, and the unit fits into the machine base or beside the hydraulic power unit, including retrofits onto machines already in service.
- Heavy construction and mining equipment: continuous thermal load on the hydraulic circuit, with the cooler squeezed into a confined machinery space and fed from an industrial water source.
- Lubrication circuits and gearboxes: the same unit works as a lube oil cooler on bearing and gearbox lubrication lines, where temperature is held for viscosity rather than for hydraulic response.
- Centralised hydraulic stations: one shell cools a large reservoir or a group of machines from a single water loop — a layout hydraulic oil cooler manufacturers are asked for wherever a plant runs one cooling circuit across several power units.
- Retrofit from air-cooled: where a water line has since been run to the machine, swapping a fan-cooled unit for a shell takes the fan noise and the dust-clogged fins out of the workshop.
Model Range & Flow Coverage
| Model | Design flow (L/min) | Oil connection | Water connection | Fixing holes | Typical duty |
|---|
| DC-303 | 100 | 1" | 3/4" | 4 × M8 | Small power units and machine-tool hydraulics |
| DC-307 | 100 | 1" | 3/4" | 4 × M8 | Hydraulic power units on rubber and plastics moulding machinery |
| DC-406 | 200 | 1¼" | 3/4" | 6 × M8 | Centralised hydraulic stations, press and forming circuits |
| DC-514 | 300 | 1½" | 1" | 6 × M8 | Injection moulding and extrusion lines |
| DC-530 | 300 | 1½" | 1" | 6 × M8 | Ships, steel mill equipment and heavy construction machinery |
| DC-640 | 400 | 2" | 1½" | 8 × M8 | Heavy presses and large hydraulic power units |
| DC-8100 | 600 | 2½" | 1½" | 8 × M10 | Large marine equipment and heavy-duty industrial hydraulic systems |
| DC-10110 | 800 | DN65 | 1½" | 12 × M10 | Central cooling on very large circuits |
Type parameter list
| Model NO | A | C | B | R | D | E | H | J | K | L | M | N | X | S | F | Design Flow (L/min) |
|---|
| DC-303 | 319 | 55 | 152 | 89 | 120 | 60 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-304 | 391 | 55 | 224 | 89 | 120 | 130 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-305 | 463 | 55 | 296 | 89 | 120 | 200 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-306 | 535 | 55 | 368 | 89 | 120 | 270 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-307 | 607 | 55 | 440 | 89 | 120 | 340 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-308 | 679 | 60 | 512 | 89 | 120 | 410 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-309 | 751 | 60 | 584 | 89 | 120 | 480 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-310 | 823 | 60 | 656 | 89 | 120 | 550 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-311 | 895 | 60 | 728 | 89 | 120 | 620 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-312 | 967 | 60 | 800 | 89 | 120 | 690 | 84 | 34 | 13 | 95 | 57 | 11-20 waistband | 4-M8 | 1" | 3/4" | 100 |
| DC-406 | 351 | 60 | 160 | 114 | 150 | 50 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-407 | 403 | 60 | 212 | 114 | 150 | 100 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-408 | 475 | 60 | 284 | 114 | 150 | 170 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-409 | 531 | 60 | 340 | 114 | 150 | 225 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-410 | 575 | 60 | 384 | 114 | 150 | 270 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-411 | 619 | 60 | 428 | 114 | 150 | 310 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-413 | 691 | 60 | 500 | 114 | 150 | 380 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-414 | 731 | 60 | 540 | 114 | 150 | 420 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-415 | 757 | 60 | 572 | 114 | 150 | 450 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-417 | 895 | 60 | 710 | 114 | 150 | 585 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-418 | 901 | 60 | 716 | 114 | 150 | 590 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-419 | 973 | 60 | 788 | 114 | 150 | 660 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-421 | 1045 | 60 | 860 | 114 | 150 | 730 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-426 | 1249 | 60 | 1064 | 114 | 150 | 930 | 104 | 30 | 13 | 150 | 95 | 11-20 waistband | 6-M8 | 1¼" | 3/4" | 200 |
| DC-514 | 502 | 70 | 270 | 140 | 180 | 170 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-518 | 638 | 70 | 406 | 140 | 180 | 305 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-522 | 746 | 70 | 514 | 140 | 180 | 410 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-526 | 854 | 70 | 622 | 140 | 180 | 515 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-530 | 962 | 70 | 730 | 140 | 180 | 620 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-534 | 1070 | 70 | 838 | 140 | 180 | 725 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-538 | 1178 | 70 | 946 | 140 | 180 | 830 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-542 | 1286 | 70 | 1054 | 140 | 180 | 930 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-546 | 1398 | 70 | 1162 | 140 | 180 | 1030 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-550 | 1502 | 70 | 1270 | 140 | 180 | 1130 | 118 | 30 | 13 | 175 | 130 | 11-20 waistband | 6-M8 | 1½" | 1" | 300 |
| DC-640 | 825 | 110 | 570 | 168 | 215 | 380 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-650 | 975 | 110 | 720 | 168 | 215 | 530 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-660 | 1125 | 110 | 870 | 168 | 215 | 680 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-670 | 1295 | 110 | 1040 | 168 | 215 | 850 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-680 | 1455 | 110 | 1200 | 168 | 215 | 1010 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-690 | 1615 | 110 | 1360 | 168 | 215 | 1170 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-6100 | 1785 | 110 | 1530 | 168 | 215 | 1340 | 142.5 | 30 | 13 | 203 | 160 | 14-17 waistband | 8-M8 | 2" | 1½" | 400 |
| DC-860 | 880 | 120 | 565 | 219 | 270 | 410 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-870 | 952 | 120 | 637 | 219 | 270 | 485 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-885 | 1096 | 120 | 781 | 219 | 270 | 630 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8100 | 1239 | 120 | 924 | 219 | 270 | 770 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8110 | 1349 | 120 | 1034 | 219 | 270 | 880 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8120 | 1439 | 120 | 1124 | 219 | 270 | 970 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8130 | 1549 | 120 | 1234 | 219 | 270 | 1080 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8145 | 1659 | 120 | 1344 | 219 | 270 | 1190 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8160 | 1829 | 120 | 1514 | 219 | 270 | 1360 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-8170 | 1949 | 120 | 1634 | 219 | 270 | 1480 | 185 | 40 | 14 | 270 | 204 | 18-26 waistband | 8-M10 | 2½" | 1½" | 600 |
| DC-10110 | 638 | 120 | 638 | 273 | 315 | 420 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10125 | 800 | 120 | 800 | 273 | 315 | 580 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10130 | 835 | 120 | 835 | 273 | 315 | 615 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10150 | 909 | 120 | 909 | 273 | 315 | 690 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10165 | 1019 | 120 | 1019 | 273 | 315 | 800 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10180 | 1109 | 120 | 1109 | 273 | 315 | 890 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10200 | 1219 | 120 | 1219 | 273 | 315 | 1000 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10210 | 1329 | 120 | 1329 | 273 | 315 | 1100 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10225 | 1409 | 120 | 1409 | 273 | 315 | 1190 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10240 | 1499 | 120 | 1499 | 273 | 315 | 1280 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10260 | 1619 | 120 | 1619 | 273 | 315 | 400 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10280 | 1739 | 120 | 1739 | 273 | 315 | 1520 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
| DC-10300 | 1879 | 120 | 1879 | 273 | 315 | 1660 | 215 | 40 | 14 | 330 | 230 | 18-26 waistband | 12-M10 | DN65 | 1½" | 800 |
Servicing & Spare Parts
A water-cooled cooler gives very little warning, so the servicing question is really about being ready. Keep a set of end-cap gaskets and port seals on the shelf for every unit on site: they are small, they are the part disturbed every time the water side is opened, and having them to hand turns a two-day wait into a same-shift job.
When a unit has to come out, isolate it, drain the water side and blank the ports so the oil circuit stays clean. Note the model reference and the details on the specification label fixed to the shell before you call us — that label is what lets us match the build and send the right parts.
If a tube or a seal has failed, photographs of the tube sheet, the label and the affected area are usually enough for us to advise on repair against replacement, and to say which spare parts the job needs. Sudden oil cooler hydraulic faults — a step change in temperature, an oil weep at a flange — are far more often a joint or a seal than a damaged bundle, and they are the lower-cost ones to fix when the parts are already on the shelf.
Packaging & Delivery
- Crated for transit: each unit is packed individually in reinforced, shock-absorbent crating. This is how hydraulic oil cooler manufacturers pack heavy heat-exchange equipment: the shell is braced inside the crate, the flange faces are protected, and nothing shifts in transit.
- Shipped as a complete assembly: water cooled oil coolers leave here with the mounting brackets fitted and the ports capped, so there is nothing to re-assemble on site beyond making the connections.
- Factory-direct dispatch: standard orders typically move through production in about 7 days; the exact ship date is confirmed against your order and destination when it is placed.
- Documentation in the crate: technical and export documentation travels with the shipment, so customs clearance and site installation are not held up waiting for paperwork.
- Custom builds packed to the same standard: a custom oil cooler with a different tube grade, port arrangement or mounting is crated the same way, and the drawing is issued for your approval before the build starts.
- Tell us about site access: a shell-and-tube unit is heavy for its size and usually needs a pallet truck or a hoist on arrival; if the delivery point has restricted access, say so before dispatch and we will pack and label for it.
- Terms to confirm: payment terms, freight arrangement and warranty cover are confirmed in writing with your sales contact when the order is placed, so nothing is assumed from a catalogue page.
- Document | What it gives you --- | --- Dimension drawing, issued per model | Overall length, centre heights, port centres and fixing-hole pitch, marked A to S Model parameter table | Design flow, oil and water connection sizes and fixing holes for every model in the series DC Series cooler sizing and selection guide | How to work from a heat load and a flow rate to a model Installation and start-up notes | Piping, flushing, venting and the four baseline temperature readings to record Pressure test record | Ask for it to be issued with your order Export documentation | Packing list, invoice and customs paperwork, shipped with the unit
Technical Support & Model Matching
Buying hydraulic components for a machine you are building usually comes down to one question: which model actually fits. Tell our technical team what the machine has to do and the conditions it works in, and they will work through the options with you, confirm the model and send the drawing for approval before you order. Where nothing in the current range lines up, we build to your requirements under ODM/OEM. The same engineers stay reachable after delivery for installation and commissioning questions, fault finding and spare parts, from a 20-person team in Foshan serving buyers worldwide.
The DC Series is manufactured under ISO 9001, ISO 14001 and ISO 10012 quality management systems — quality, environmental and measurement management respectively. In practice that means the tube bundle, the shell and the seals are made to a written specification and measured against it, rather than to a fitter's judgement on the day. Every unit is pressure-tested before it is packed. On a shell-and-tube cooler that is the test that matters: it proves the oil side and the water side are genuinely separate, which is the failure that stops a machine rather than merely slowing it down. Because we are the oil cooler manufacturers rather than a reseller, the pressure test, the final inspection and the packing all happen at the same works that builds the shell. Documentation is issued with the unit where a buyer needs it for a quality file — a test record, a dimensional report, a wetted-materials statement. That is the paperwork hydraulic oil cooler manufacturers are asked for on marine, steel and power-generation contracts, and it is what we work to as standard. The construction is engineered for an operational life of ten years and more, provided the tubes are cleaned on schedule and the water stays within the grade the bundle was chosen for.
FAQ
How does a water-cooled cooler compare with an air-cooled unit for the same duty?
Water cooled oil coolers remove the same heat in a smaller, quieter envelope, because water carries far more heat per litre than air. The trade is that the site has to supply water and somewhere to return it, and the water side needs to be reachable for cleaning. If the machine has a water line, the shell-and-tube unit is normally the compact answer; if it has none and none can be added, an air-cooled cooler is the correct choice.
Can I run it on sea water or process water instead of fresh water?
Standard units are built for fresh water — a cooling tower, a closed loop or a treated plant supply. Sea water, brackish water and specific process streams need a different tube grade, usually copper-nickel, and occasionally different water-side materials. Send the source, the chloride level and the usual water temperature with your enquiry and the grade is specified for that stream.
What materials are the tubes and the wetted parts made from?
The tube bundle is copper or copper-nickel alloy, selected against the water rather than the oil. The body is a painted cylindrical shell with bolted, flanged end caps at both ends, and the oil side and water side are separated by sealed joints that can be opened for tube access. Both grades resist internal and external corrosion.
Can it be built to suit my hydraulic system rather than a catalogue model?
Yes. The series already covers a wide spread of flows and connection sizes, and where a circuit sits outside that spread the unit is built to your parameters — port sizes, mounting arrangement and tube grade for the water you have. A custom oil cooler is built from your duty figures and drawing, and you approve that drawing before the build starts.
Can the cooler be mounted vertically if space is tight?
The unit works in either orientation, and what usually decides it is where the pipework runs and which end you need to reach. The end caps have to stay accessible, because that is the end that opens for tube cleaning. Settle the orientation before the pipework goes in — changing it afterwards means re-making both connections.
How often do the tubes need cleaning, and what happens if they are not?
Inspect the water side on the same cycle as the rest of the plant's heat exchangers, and clean when the oil outlet temperature starts to creep or the water-side pressure drop rises. Scale and silt insulate the tubes, so an oil cooler hydraulic temperature problem that builds over weeks is nearly always dirt rather than a failed bundle. Cleaning on schedule is also what keeps the ten-year service expectation realistic.
Will it work on a lubrication circuit as well as a hydraulic one?
Yes. It is used as a lube oil cooler on gearbox, bearing and turbine lubrication lines as readily as on a hydraulic circuit. Lubrication duty often runs hotter and at a steadier flow than a hydraulic circuit, so say which duty the unit is for when you specify and the model is matched to that rather than to the other.